Signal-10 Operation Principles
35 www.bolid.com
№ Program Description
Initial
Condition
29
Switch On
Upon Arming
If at least one related loop is armed the relay is
switched on
Off
30
Switch Off
Upon Arming
If at least one related loop is armed the relay is
switched off
On
31
Switch On
Upon Auxiliary Loop
Breaking
In case of an Auxiliary Alarm the relay is switched
on
Off
32
Switch Off
Upon Auxiliary Loop
Breaking
In case of an Auxiliary Alarm the relay is switched
off
On
33 ASPT-1
The relay is switched on for a specified time if the
alarm loop has got Fire Alarm status and there are
no broken Auxiliary alarm loops. If an Auxiliary
alarm loop is broken before Relay Activation De-
lay has not yet expired then, when the loop is re-
covered, the relay output will be switched on for a
specified time. (That is, breaking of the Auxiliary
loop temporary blocks activation delay counting.)
Off
34 ASPT-А
The relay is switched on for a specified time if two
or more alarm loops related with the output have
got Fire Alarm status and there are no broken
Auxiliary alarm loops. A broken Auxiliary loop
cancels activation the relay, that is, the Auxiliary
loop being recovered, the output will NOT be
switched on
Off
35 ASPT-А1
The relay is switched on for a specified time if the
alarm loop has got Fire Alarm status and there are
no broken Auxiliary alarm loops. A broken Auxilia-
ry loop cancels activation the relay, that is, the
Auxiliary loop being recovered, the output will
NOT be switched on
Off
36
Switch On Upon
Temperature Increase
If the alarm loop has got the High Temperature **
status the relay is switched on
Off
37
Switch On Upon
Temperature Decrease
If the alarm loop has got the Low Temperature **
status the relay is switched on
Off
NOTES:
* The relay behavior is defined by conditions of the group of related alarm loops
** Only that alarm loop which is programmed with the Type 12 (Auxiliary Programmable) can enter
High Temperature or Low Temperature condition